LCD graphics display has text and mimic diagrams that display modes of operation, system parameters and alarms. Connect the device to a network using a 10 or 100 BASE-T connection. Green mode bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. Battery failure notification provides early-warning fault analysis on batteries enabling timely preventive maintenance. Automatic internal bypass supplies utility power to the connected loads in the event of a UPS power overload or fault. Scalable runtime allows additional run time to be quickly added as needed. Intelligent battery management maximizes battery performance, life, and reliability through intelligent, precision charging.
- LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms. - 10/100 BaseT ?onnection
Connect the device to a network using a 10 or 100 BaseT connection. - Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection. - Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance. - Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault. - Scalable runtime
Allows additional run time to be quickly added as needed. - Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging. - Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced - Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power. - Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature. - Network manageable
Provides remote power management of the UPS over the network. - InfraStruXure Manager ?ompatible
Enables centralized management via the APC InfraStruXure Manager. - SmartSlot
Customize UPS capabilities with management cards. - LED status indicators
Quickly understand unit and power status with visual indicators. - Serial connectivity
Provides management of the UPS via a serial port. - Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS. - Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment. - Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP. - User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR). - Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced. - Predicitive failure notification
Provides early-warning fault analysis ensuring proactive component replacement. - Disconnected battery notification
Warns when a battery is not available to provide backup power. - Audible alarms
Provides notification of changing utility power and UPS power conditions. - Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery. - Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances. - Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling. - Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used. - Cold-start capable
Provides temporary battery power when the utility power is out. - Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
General
Device Type
UPS - rack-mountable / external
Power Device
Frequency Provided
50/60 Hz
Frequency Required
45 - 65 Hz
Input Connectors
1 x hardwire 3-wire (1PH + N + G)
Power Output Connectors Details
6 x power IEC 60320 C13 ¦ 4 x power IEC 60320 C19 ¦ 2 x IEC connector
Output Voltage
AC 230 V ± 3% - 50/60 Hz
Power Capacity
4500 Watt / 5000 VA
Surge Energy Rating
480 Joules
Battery
Run Time (Up To)
4 min at full load ¦ 11.8 min at half load
Features
Maintenance free, sealed, leak-proof
Networking
Remote Management Interface
Ethernet 10/100, USB
Expansion / Connectivity
Interfaces
1 x management (Ethernet) - RJ-45 ¦ 1 x management (USB) - 4 pin USB Type B ¦ 1 x EPO (emergency power off) ¦ 1 x serial - RJ-45
Expansion Slots
1 (total) / 1 (free) x SmartSlot
Miscellaneous
Features
Audible alarm, LCD display
Compliant Standards
C-Tick, VDE, IEC 60950, EN 50091-2, RoHS, EN 50091-1, REACH, EN 62040-2, IP20, EAC
Software / System Requirements
Software Included
APC PowerChute Business Edition
Manufacturer Warranty
Service & Support
Limited warranty - 3 years ¦ Limited warranty - batteries - 2 years
Environmental Parameters
Min Operating Temperature
0 °C
Max Operating Temperature
40 °C
Humidity Range Operating
0 - 95% (non-condensing)
Dimensions & Weight
Dimensions & Weight (Shipping)